Prerequisites
T
here are no interferences or obstacles in the protective field of the safe multi‐
beam scanner. Where there are unavoidable obstacles, additional protective mea‐
sures are applied.
An area with a distance of up to 250 mm from the front screen of the safe
multibeam scanner must be free of objects when switched on. Otherwise, a conta‐
mination error (recoverable error) can occur and the OSSDs will not switch to the
ON state.
If people can stay between the protective device and the hazardous point without
being detected, additional protective measures (e.g., external restart interlock) are
applied.
Reaching under, over and around, crawling beneath and stepping over the safe
multibeam scanner, as well as moving it, are prevented.
Complementary information
C
ertain optical and electromagnetic ambient conditions can affect the safe multibeam
scanner and thus reduce the availability of the machine.
Examples:
Condensation on the front screen
Strong electrical fields (e.g. welding cables or induction cables)
Further topics
"Mount
ing", page 37
"Dimensional drawings", page 79
4.3.1 Protection from interference
Interference by lasers
L
aser beams from other laser sources can affect the safe multibeam scanner and thus
reduce the availability of the machine.
Measures to increase availability:
b
Avoid foreign laser beams in the scan plane.
b
Set multiple sampling to the highest value permitted in your application, taking the
minimum distances into account.
Interference by strong ambient light
St
rong external light sources in the scan plane can affect the safe multibeam scanner
and thus reduce the availability of the machine.
Measures to increase availability:
b
Avoid external light sources in the scan plane.
b
Avoid direct sunlight in the scan plane.
b
Do not position halogen lights, infrared light sources or stroboscopes directly on
the scan plane.
Mutual interference of safe multibeam scanners
W
hen using several safe multibeam scanners, they can interfere with each other. To
avoid mutual interference in all cases, you need to choose a suitable mounting method.
Suitable mounting methods:
b
Offset mounting so that the scan planes are on different planes
b
Slightly inclined, tilted mounting, so that the scan planes intersect one another
PROJECT PLANNING 4
8025936/2021-01-08 | SICK O P E R A T I N G I N S T R U C T I O N S | scanGrid2 I/O
17
Subject to change without notice

Table of Contents

Other manuals for SICK scanGrid2 I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK scanGrid2 I/O and is the answer not in the manual?

SICK scanGrid2 I/O Specifications

General IconGeneral
BrandSICK
ModelscanGrid2 I/O
CategoryScanner
LanguageEnglish

Related product manuals