Visual check of the machine and the protective device
R
ecommended approach:
b
Check whether the machine or the protective device has been modified or manipu‐
lated so that the effectiveness of the protective device may be impaired.
b
In particular, check the following points:
°
Has the machine been retrofitted?
°
Have machine parts been removed?
°
Have modifications been made to the surroundings of the machine?
°
Are there any defective cables or flying leads?
°
Have the protective device or its parts been dismantled?
°
Is the protective device damaged?
°
Is the protective device severely contaminated?
°
Is the front screen contaminated, scratched or destroyed?
°
Has the protective device’s alignment been changed?
°
Are there any objects (e.g. cables, reflective surfaces) in the protective field?
If one of the points applies, the machine should be shut down immediately. In this
case, the machine and the protective device must be checked by appropriately qualified
safety personnel.
4 P
ROJECT PLANNING
36
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 I/O 8025936/2021-01-08 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK scanGrid2 I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK scanGrid2 I/O and is the answer not in the manual?

SICK scanGrid2 I/O Specifications

General IconGeneral
BrandSICK
ModelscanGrid2 I/O
CategoryScanner
LanguageEnglish

Related product manuals