Loosen the quick-release bolt at the top of the device and take the connector cover
off [picture A]. The DC link connections are flat copper bars with drill holes.
Feed the DC link cables (UB+, UB−) through the top connector cover accord-
ing to the arrows in the picture. Then, connect the cables using ring cable lugs
[picture A].
a. bolt size = M8
b. tightening torque = 23 Nm
Loosen the 2 quick-release bolts at the bottom of the device and take the connector
cover off [picture B]. The motor phase connections are flat copper bars with drill
holes.
Feed cables for the motor phases (U, V, W) through the bottom connector cover ac-
cording to the arrows in the picture. Then, connect the cables using ring cable lugs
[picture B].
a. bolt size = M8
b. tightening torque = 23 Nm
Also refer to the connection example Motor Phases.
Put the top connector cover back on the device and tighten it with the quick-release
bolt.
Put the bottom connector cover back on the device and tighten it with the 2 quick-
release bolts.
131Drive System SD2 - Hardware Description
Connector Pin Assignment

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIEB & MEYER SD2 Series and is the answer not in the manual?

SIEB & MEYER SD2 Series Specifications

General IconGeneral
BrandSIEB & MEYER
ModelSD2 Series
CategoryControl Unit
LanguageEnglish

Related product manuals