EasyManuals Logo

SIEB & MEYER SD2 Series User Manual

Default Icon
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
Power Supply Unit PS2
9.4.2 Technical Data
Device variant 0362193F
min. 3 × 230 V
AC
-20 %
Mains supply L1, L2, L3
(1)
three-phase
max. 3 × 480 V
AC
+10 %
230 V
AC
24.5 kW
400 V
AC
60 kW
Max. rated power
480 V
AC
72 kW
Logic supply 18 to 28 V
DC
(max. 0.4 A at 24 V
DC
)
Protective fuse L1, L2, L3 three-phase max. 3 × 100 A
Ballast resistor 230 V
AC
, min. 3.3 Ω
≥ 400 V
AC
, min. 6 Ω
Rated power of ballast circuit 10 kW
Pulse power of ballast circuit 106 kW
Precharge resistor internal min. 100 Ω / PTC
Capacity of DC link internal 2800 µF
Precharge resistor external min. 50 Ω
Power of external precharge resistor at 50 Ω P
rated
= 200 W
P
pulse
= 7.7 kW
Power of external precharge resistor at 100 Ω P
rated
= 100 W
P
pulse
= 3.8 kW
Capacity of DC link external max. 60 mF
Precharge time at 60 mF and 100 Ω 36 s
Precharge frequency max. 1 x in 2 minutes
Discharge time of internal capacity < 50 V > 16 minutes
Max. heat sink temperature 75° C
Ambient temperature 0 to 40 °C without power reduction, max. 60 °C
Above 40 °C the power must
be reduced by 1.5 % per 1 °C.
Humidity up to 85 % (without moisture condensation)
Max. weight 9.35 kg
(1)
For power chokes refer to Manufacturers.
96 Drive System SD2 - Hardware Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIEB & MEYER SD2 Series and is the answer not in the manual?

SIEB & MEYER SD2 Series Specifications

General IconGeneral
BrandSIEB & MEYER
ModelSD2 Series
CategoryControl Unit
LanguageEnglish

Related product manuals