8.2.2 Technical Data
Note
The compact devices 0362131xxy are to be operated with an external line filter.
SIEB & MEYER offers, for example, line filters by TDK & EPCOS group (see Manufac-
turers). For detailed information on line filters refer to the documentation “Unit Assembly
Complying EMC”.
Device variant 0362131xxC 0362131xxF
Current range DDC SSC DDF SSF
Rated current (8 kHz) 16 A
p
+ 16 A
p
/
11 A
rms
+ 11 A
rms
16 A
p
+ 16 A
p
/
11 A
rms
+ 11 A
rms
10 A
p
+ 10 A
p
/
7 A
rms
+ 7 A
rms
10 A
p
+ 10 A
p
/
7 A
rms
+ 7 A
rms
Peak current of the output
stages
20 A
S
+ 20 A
S
/
14 A
rms
+ 14 A
rms
60 A
p
+ 60 A
p
/
42 A
rms
+ 42 A
rms
20 A
S
+ 20 A
S
/
14 A
rms
+ 14 A
rms
60 A
p
+ 60 A
p
/
42 A
rms
+ 42 A
rms
Max. time for peak current 5 s 1 s 5 s 1 s
Max. temperature of the output
stage
75° C
Max. output frequency 2000 Hz
Output frequency stability ≤ 0.2 %
Mains supply (1-phase) 1 × 230 V
AC
+10 % / -33 %
50 Hz / 60 Hz
–
Mains supply (3-phase) 3 × 230 V
AC
+10 % / -33 %
50 Hz / 60 Hz
3 × 480 V
AC
+10 % / -33 %
50 Hz / 60 Hz
Rated DC current of power sup-
ply unit
max. 20 A
Peak DC current of power sup-
ply unit
50 A for 1 s
Power rating 2.5 kVA (1-phase mains supply)
6.4 kVA (3-phase mains supply)
11.2 kVA
DC link voltage 40 to 325 V
DC
+10 % 40 to 680 V
DC
+10 %
Logic supply 18 to 28 V
DC
Power loss logic unit 12 W
Power loss of power unit Max. 5 % of the output motor power, at least 20 W
Min. external ballast resistor 15 Ω 33 Ω
Ballast threshold 380 V
DC
800 V
DC
Overvoltage threshold 410 V
DC
850 V
DC
Undervoltage threshold 40 V
DC
Ambient temperature range 5 °C to 60 °C at a maximum relative humidity of 85 % (without moisture condensation),
100 % rated current up to max. 40 °C. At higher temper-
atures the power must be reduced by -1.5 % per 1 °C.
IP Code IP20
Max. weight 7.5 kg
81Drive System SD2 - Hardware Description
Compact Devices