Single-axis Drive Amplifiers
6.5.2 Technical Data
Device variant 0362111SF
Device version ≥ 9.100
8 kHz 285 A
p
/ 201 A
rms
Max. rated current of the output stage
with water cooling (10 l/min, max.
30 °C)
16 kHz
210 A
p
/ 148 A
rms
Peak current of the output stage
358 A
p
/ 253 A
rms
Max. time for peak current 25 s
Max. temperature of the output stage in module 85 °C
Max. output frequency 2000 Hz
Output frequency stability ≤ 0.2 %
DC link voltage 40 to 680 V
DC
+10 %
Logic supply 24 V
DC
±5 %
Power loss logic unit 20 W
Efficiency of power unit at least 0.96
Overvoltage threshold 850 V
DC
Undervoltage threshold 40 V
DC
Ambient temperature range 5 °C to 60 °C at a maximum relative humid-
ity of 85 % (without moisture condensation)
100 % rated current up to max. 40 °C. At higher temper-
atures the power must be reduced by 1.5 % per 1 °C.
Heat sink Aluminum heat sink with 2 copper tubes
Coolant connection 1/2" internal thread
Water cooling
Flow rate 10 l/min (temperature of coolant: max. 30 °C)
IP Code IP20
Max. weight 11 kg
44 Drive System SD2 - Hardware Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIEB & MEYER SD2 Series and is the answer not in the manual?

SIEB & MEYER SD2 Series Specifications

General IconGeneral
BrandSIEB & MEYER
ModelSD2 Series
CategoryControl Unit
LanguageEnglish

Related product manuals