EasyManuals Logo
Home>SIEB & MEYER>Control Unit>SD2 Series

SIEB & MEYER SD2 Series User Manual

Default Icon
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
7.3.2 Technical Data
Device variant 0362113xxC 0362113xxF
Current range DDC EEC CCF DDF EEF
Rated current (8 kHz) 14 A
p
+ 14 A
p
/
10 A
rms
+ 10 A
rms
14 A
p
+ 14 A
p
/
10 A
rms
+ 10 A
rms
9 A
p
+ 9 A
p
/
6.4 A
rms
+ 6.4 A
rms
10 A
p
+ 10 A
p
/
7 A
rms
+ 7 A
rms
10 A
p
+ 10 A
p
/
7 A
rms
+ 7 A
rms
Rated current (16 kHz) -- -- -- 8.5 A
p
+ 8.5 A
p
/
6 A
rms
+ 6 A
rms
--
Peak current of the output
stages (8 kHz)
20 A
p
+ 20 A
p
40 A
p
+ 40 A
p
10 A
p
+ 10 A
p
20 A
p
+ 20 A
p
40 A
p
+ 40 A
p
Peak current of the output
stages (16 kHz)
-- -- -- 20 A
p
+ 20 A
p
--
Max. time for peak current 5 s 2 s 5 s 5 s 2 s
Max. temperature of the output
stage
75° C
Max. output frequency 2000 Hz
Output frequency stability ≤ 0.2 %
DC link voltage 40 to 325 V
DC
+10 % 40 to 680 V
DC
+10 %
Logic supply 18 to 28 V
DC
Power loss logic unit 12 W
Power loss of power unit Max. 5 % of the output motor power, at least 20 W
Overvoltage threshold 410 V
DC
850 V
DC
Undervoltage threshold 40 V
DC
Ambient temperature range 5 °C to 60 °C at a maximum relative humidity of 85 % (without moisture condensation),
100 % rated current up to max. 40 °C. At higher temper-
atures the power must be reduced by -1.5 % per 1 °C.
IP Code IP20
Max. weight 5.7 kg
69Drive System SD2 - Hardware Description
Double-axis Drive Amplifiers

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIEB & MEYER SD2 Series and is the answer not in the manual?

SIEB & MEYER SD2 Series Specifications

General IconGeneral
BrandSIEB & MEYER
ModelSD2 Series
CategoryControl Unit
LanguageEnglish

Related product manuals