Commissioning (software)
5.9 Commissioning with PROFIBUS DP
Control Units CU240S
Operating Instructions, 11/2006, A5E00766042B AA
5-83
Used telegram types
The following telegrams can be set via parameter P0922:
Standard telegrams
The standard telegrams are structured in accordance with the PROFIdrive Profile. The
internal process data links are set up automatically in accordance with the telegram number
setting.
Telegram 1 Speed control, 2 words
Telegram 20 Speed control, VIK/NAMUR
Manufacturer-specific telegrams
The manufacturer-specific telegrams are structured in accordance with internal company
specifications. The internal process data links are set up automatically in accordance with
the telegram number setting.
Telegram 350 Speed control, 4 words
Telegram 352 Speed control, PCS7
Device-specific telegrams
The send and receive telegrams can be configured as required by using BICO technology to
interconnect the send and receive process data.
Telegram 999 Free interconnection via BICO (up to 6 dat words)
5.9.4 Standard Telegram structure
BICO connection
When a telegram is selected, the corresponding BICO connection parameters will be fixed
and cannot be changed (except P0701 and the following digital inputs). If P0922 = 999, it
keeps the actual BICO connection parameters but now BICO parameters can be changed.