Functions
8.11 JOG
Control Units CU240S
8-50 Operating Instructions, 11/2006, A5E00766042B AA
8.11 JOG
Data
Parameter range: P1055 … P1061
Warnings: A0923
Faults: -
Function chart number: FP5000
Description
The JOG function is used as follows:
● To check the functionality of the motor and inverter after commissioning has been
completed (the first traversing motion, checking the direction of rotation, etc.)
● Positioning a motor or a motor load into a specific position
● Traversing a motor, e.g. after a program has been interrupted
The motor is traversed using this function by entering fixed frequencies P1058, P1059. The
JOG mode can be selected using the operator panel, digital inputs or the serial interface. An
ON/OFF command is not used to move the motor, but instead when the "JOG keys" are
pressed movement takes place. These "JOG keys" are selected using the BICO parameters
P1055 and P1056. The JOG function can be disabled via P1057.