Current output configuration
The following process values can be assigned to the current output:
Mass flow
Volume flow
Standard volume flow
Density
Temperature
Fraction A (Volume flow or Mass flow)
Fraction B (Volume flow or Mass flow)
Fraction A %
Fraction B %
Control valve *
The process variable listed above with * is not available to be allocated to the 4 to 20 mA output
on Channel 1. All process variables are available through bus communication (SV, TV and QV
variables) and on all of Channels 2 to 4.
The accuracy specified for the analog output signal applies only within the range 4 to 20 mA.
Lower limit (4 mA) and upper limit (20 mA) can be assigned to any specific flow values.
Functions
8.6 Inputs and outputs
MASS 2100 & FC300 (FCT030)
144 Operating Instructions, 06/2017, A5E39789040-AA