ID/
Icons
Diagnostic Action Comment
223 Modbus Invalid coil configuration. Modbus coils are not
configured correctly. Check coil allocation.
285 Datalogging DATALOGGING 30 DAYS LEFT
286 Datalogging DATALOGGING 7 DAYS LEFT
287 Datalogging DATALOGGING SDCARD FULL
288 Frame temperature simulated Value simulated. Disable 'Simulation' to return
to normal operation.
298 Standard volume flow simulated Value simulated. Disable 'Simulation' to return
to normal operation.
10.3 Operation troubleshooting
10.3.1 How do I copy application setup from one device to another?
1. Remove the SensorFlash from the source device and insert the SensorFlash into the
destination device. The destination device disables the backup and signals an alarm.
2. Enter menu item 3.3.1 Copy configuration, select "OK" and press
to execute the copying
and move all the application setup parameters from the SensorFlash to the device. Backup
is still disabled and alarm signaled.
3. Remove the SensorFlash from the destination device and insert the original SensorFlash.
The device synchronizes the parameters to the SensorFlash and the alarm is cleared.
Diagnosing and troubleshooting
10.3 Operation troubleshooting
MASS 2100 & FC300 (FCT030)
208 Operating Instructions, 06/2017, A5E39789040-AA