3.4 Features
The device can be used as HART slave in operation on SIEMENS SIMATIC S7/PCS7 or
third party automation systems
Available in compact and remote design
Full graphical local display (HMI)
SensorFlash (SD card) for memory backup and documentation storage (certificates etc.)
One current output a standard
Channel 1: Current output with HART, Modbus, Profibus
The available process values for Channel 1 are restricted to those which are safety
certified: Massflow, Volumeflow and Density. For access to other process values,
including Process Temperature, an extra channel is required at ordering.
Three optional input/output channels:
Channel 2: Signal output; can be parameterized for:
Current output (0/4-20 mA)
Pulse output
Frequency output
One on/off valve output
Two on/off valves output
Alarm, status, flow direction
Channels 3 and 4: Signal output (as channel 2)
Pulse or frequency redundancy mode ((only channel 3 linked to channel 2 with 90° or
180° redundancy))
Channels 3 and 4: Relay output; can be parameterized as:
One on/off valve output
Two on/off valves output
Alarm, status, flow direction
Channels 3 and 4: Signal input; can be parameterized as:
Dosing control
Totalizer control (resetting of totalizers)
Zero adjustment
Setting or freezing a frequency at the digital outputs if these are set to 'Frequency'
Current, frequency, and pulse outputs with configurable fail safe mode
High immunity against process noise
Fast response to step changes in flow
High update rate (100 Hz) on all process values