B.4 Totalizer
Table B-7 Totalizer 1
HMI menu ID Parameter Description Default value
[unit]
Value range Access
level
2.3.1.1 Process value Select process value for totaliza‐
tion.
Mass flow
● Mass flow
● Volume flow
● Standard
volume flow
● Fraction A
● Fraction B
User
2.3.1.2 Unit 1) Select unitss for triggered total‐
izer 1. Units are not applied at
communication interface.
kg Kg, t, STon, T, oz,
lb, Custom
User
2.3.1.2 Unit 2) Select unitss for triggered total‐
izer 1. Units are not applied at
communication interface.
L L, hl, m³, gal, gal
(UK),bbl31.5,
bbl31, bbl42, in³,
ft³, yd³, bush, Cus‐
tom
User
2.3.1.2 Unit 3) Select unitss for triggered total‐
izer 1. Units are not applied at
communication interface.
SL Nl, Nm³, SI, Sft³,
Sm³, Custom
User
2.3.1.3 Custom units Define a name for the custom
units. The custom units can then
be selected in the units list.
Sensor depend‐
ent
User
2.3.1.4 Custom conversion fac‐
tor
Define a mass factor for the cus‐
tom units. The factor is based on
SI mass units kg
1.00 User
2.3.1.5 Decimal Places 1) 2) 3) Define the decimal point for the
process value triggered in the
Local display.
2
● Auto
● No decimal
place
● 1
● 2
● 3
● 4
● 5
● 6
User
2.3.1.6 Direction Select totalizing direction. Forward count‐
ing
● Forward
counting and
backward
counting
● Forward
counting
● Backward
counting
● Hold
User
Default settings
B.4 Totalizer
MASS 2100 & FC300 (FCT030)