Table 11-18 System design
Description Specification
Measuring principle Coriolis
System architecture Compact configuration
Remote configuration
Device design
Table 11-19 Transmitter design
Description Specification
Dimension and weight See "Dimensions and weight"
Design Compact or remote
Material Aluminum with corrosion-resistant coating
Ingress protection IP67/NEMA 4X to EN/IEC 60529 (1 mH
2
O for 30
min.)
Mechanical load 18 to 1000 Hz random, 3.17 g RMS, in all direc‐
tions, to IEC 68-2-36
Torques
Table 11-20 Installation torques
Description Torque (Nm)
Pressure guard fittings
G 1/4 inch
80
Wall bracket screws 10
Transmitter to wall bracket 25
Transmitter pedestal lock screw Compact version: 10
Remote version: 6
Pedestal lock screw cap 10
Cable gland to housing (Siemens supplied, metric) 10
Note
NPT glands
When using NPT glands, the user must take care to use the supplied NPT thread adaptors.