For MASS 2100 compact with either FCT010 or FCT030
Ambient
Temperature
Maximum Process Temperature per Temperature Class (°C)
Di3 Di6 Di15
T6 T6 T6 T5 T4 T3
50°C 75 46 38 100 130 130
45°C 80 51 43 100 135 160
40°C 85 56 48 100 135 180
35°C 85 61 53 100 135 180
30°C 85 66 58 100 135 180
For dust application, maximum surface temperature = 135°C
For media temperature above 135°C surface temperature = media temperature
FC300
T3 for liquid temperatures from 135°C to 180°C.
T4 for liquid temperatures lower than 135°C.
T5 for liquid temperatures lower than 100°C.
T6 for liquid temperatures up to 65°C.
Safety notes
2.4 Use in hazardous areas
MASS 2100 & FC300 (FCT030)
Operating Instructions, 06/2017, A5E39789040-AA 25