HMI menu ID Parameter Description Default value
[unit]
Value range Access
level
2.5.9.3 Amount Define the filling amount. The
valve will be closed and filling
stopped when defined amount is
reached.
1.0
[kg]
User
2.5.9.3 Amount Define the filling amount. The
valve will be closed and filling
stopped when defined amount is
reached.
1.00
L
User
2.5.9.3 Amount Define the filling amount. The
valve will be closed and filling
stopped when defined amount is
reached.
1.00
SL
User
2.5.9.4 Decimal Places Define the decimal point for the
process value displayed in the
Local User Interface.
2
● Auto
● No Decimal
place
● 1
● 2
● 3
● 4
● 5
● 6
User
2.5.9.5 Calibration
2.5.9.5.2 Fixed Compensation Define the fixed pre-stop value.
The value is subtracted from
"Amount" to compensate for ap‐
plication delays in closing the
valves.
[kg] User
2.5.9.5.2 Fixed Compensation Define the fixed pre-stop value.
The value is subtracted from
"Amount" to compensate for ap‐
plication delays in closing the
valves.
L User
2.5.9.5.2 Fixed Compensation Define the fixed pre-stop value.
The value is subtracted from
"Amount" to compensate for ap‐
plication delays in closing the
valves.
SL User
2.5.9.6 Valve Control
2.5.9.6.1 Stage Setup Format Specify if valve control parame‐
ters are defined as absolute or
relative values (% of dosing
amount).
Relative
● Relative
● Absolute
User
2.5.9.6.2 Stage 1 Primary Open Define the dosing amount value
to open the primary valve. The
value is in % of defined dosing
amount.
0
[%]
0.0 to 100.0 User
Default settings
B.6 Dosing
MASS 2100 & FC300 (FCT030)
400 Operating Instructions, 06/2017, A5E39789040-AA