WARNING
Unprotected cable ends
Risk of explosion through unprotected cable ends in hazardous areas.
Protect unused cable ends in accordance with IEC/EN 60079-14.
WARNING
Improper laying of shielded cables
Risk of explosion through compensating currents between hazardous area and the
non‑hazardous area.
Shielded cables that cross into hazardous areas should be grounded only at one end.
If grounding is required at both ends, use an equipotential bonding conductor.
WARNING
Uncovered non-intrinsically safe circuits
Risk of explosion in hazardous areas or electric shock when working on non-intrinsically safe
circuits.
If intrinsically safe and non-intrinsically safe circuits are operated in an enclosure with the
type of protection "Increased safety Ex e", the connections of the non-intrinsically safe circuits
must be additionally covered.
Ensure that the cover of the non-intrinsically safe circuits complies with degree of
protection IP30 or higher according to IEC/EN 60529.
Separate connections of the non-intrinsically safe circuits in accordance with IEC/
EN 60079-14.
WARNING
Insufficient isolation of intrinsically safe and non-intrinsically safe circuits
Risk of explosion in hazardous areas.
When connecting intrinsically safe and non‑intrinsically safe circuits ensure that isolation
is carried out properly in accordance with local regulations for example IEC 60079-14.
Ensure that you observe the device approvals applicable in your country.
Connecting
5.1 Basic safety notes
MASS 2100 & FC300 (FCT030)
Operating Instructions, 06/2017, A5E39789040-AA 59