Building Technologies Division User Manual LMS14... CC1U7471en
6 The settings in detail 07.05.2014
6.7.1 DHW mode
Line no. Operating line
1600 DHW OptgMode
Off
On
Eco
Select the DHW mode with the operating mode button.
Note!
DHW mode can also be influenced by operating mode changeover via inputs H1 up
to H7.
Off
Continuous operation, the setpoint being the DHW Frost Protection setpoint (5 °C).
On
DHW charging takes place automatically, the setpoint being the Nominal DHW setpoint
or the Reduced DHW setpoint according to the selected kind of DHW release.
Eco
ECO mode is only used in connection with instantaneous water heaters. While the
Keep hot function is generally enabled in On mode, it is deactivated in ECO mode. In
connection with the aqua booster, ECO mode is always disabled.
DHW OptgMode