Building Technologies Division User Manual LMS14… CC1U7471en
6 The settings in detail 28.01.2015
Overview of the types of parameterization:
ACS420 online parameterization 01
ACS420 F1 parameterization 02
Canceling of ACS420 lock 04
Parameter stick parameter 51
Parameter stick online DD 52
Overview of user levels:
Siemens headquarters 01
OEM headquarters 03
OEM2 04
OEM 05
Heating expert 06
Commissioning 07
Enduser 08
Line no. Operating line
[4762.1]
OnlineDD group number
Group number of online DD used by the unit. Only online DDs of the same group can
be interchanged with the parameter stick. If a 0 is entered in the LMS14… as the online
DD group number, the unit has not yet been assigned an online DD group.
Line no. Operating line
[4689.1]
CustomNumb ParaSet
Customer number from parameter set.
When setting the parameters with the parameter stick, this number is used as a
reference to ensure that parameters of third-party devices cannot be changed.
Online DD group
number
CustomNumb ParaSet