Mounting and connecting the HMI device
4.4 Connecting the HMI device
KP8, KP8F, KP32F
60 Operating Instructions, 11/2011, A5E03284305-02
4.4.7.3 Fail-safe connection of sensor
Requirement
1 connector, see accessory kit
2 to 4 buttons as NC contact or NO contact
Procedure
The following approach is an example.
1. Connect the button as follows to the connector for the fail-safe digital inputs:
Sensor supply VS.0 for the FI.0 input
Sensor supply VS.1 for the FI.1 input
Sensor supply VS.2 for the FI.2 input
Sensor supply VS.3 for the FI.3 input
Note
External supply is not permitted for VS.0, VS.1, VS.2 and VS.3.