Process interfacing via an automation system (PLC, PC)
10.3 Control with FB 45 and Ident profile
SIMATIC MV420 / SIMATIC MV440
244 Operating Instructions, 04/2013, A5E02371045-06
WRITE-CONFIG
Table 10- 2 Command parameter
Variable Value
Config 3
Length 16
Table 10- 3 Command data appendix
Variable Value Description
Byte 1 4 Length of the subsequent sub-parameter
in hex, here 4.
Bytes 2 to
5
0
Byte 6 10 Length of the subsequent sub-parameter
in hex, here 16.
Byte 7 0
Byte 8 0
Byte 9 0
Byte 10 0x25 Setting of the MOBY operating mode.
Byte 11 2 Option
Byte 12 0
Byte 13 0
Byte 14 1 Number of MDS
Byte 15 0
Byte 16 0: INIT without program selection,
1 ... 15: Number of the program to be
started (INIT with program selection)
Table 10- 4 Command parameter
Variable Value
Config 1
Length 0 (no data appendix)
The command parameters are possible (onboard PROFINET IO) only if no communication
module is used. Corresponds to the INIT without program selection.