Process interfacing via an automation system (PLC, PC)
10.4 Control with FB79
SIMATIC MV420 / SIMATIC MV440
284 Operating Instructions, 04/2013, A5E02371045-06
Permitted values for the COMMAND parameter
Value (W#16#...) Meaning
0000 Cancel current job or no job
0001 Change program
0002 Save program
0003 Output number of the program currently selected on the reader
0004 Output the current status of the reader
0005 Reset DISA control signal
0081 Output the (possibly modified) result string
0082 Output absolute quality parameters
0083 Output absolute quality parameters and output result string
0084 Output quality parameters as classes
0085 Output quality parameters as classes and output result string
0086 Output quality parameters as classes and in absolute format
0087 Output quality parameters as classes and in absolute format and output result string
0088 Output code position
0089 Output code position and result string
008A Output code position and absolute quality parameters
008B Output code position and absolute quality parameters and output result string
008C Output code position and quality parameters as classes
008D Output code position and quality parameters as classes and output result string
008E Output code position and quality parameters as classes and in absolute format
008F Output code position and quality parameters as classes and in absolute format and output result
string
Note
To process this job, the following parameters must be set in PROFINET IO:
• Connections ➜ Integration ➜ Text: PROFINET IO
Output of the result string (except commands 4 and 5)
• Connections ➜ Integration ➜ Controller: PROFINET IO
Interface for the DISA, SEL0 to SEL3, TRN, RES, IN_OP, TRD, RDY signals