B Description of the PROFINET Configuration File
290
Commissioning PC Stations - Manual and Quick Start
Release 5/2005
C79000-G8976-C156-07
The InitiateTimeout Parameter
This parameter is specified in section [<connectionname>].
The connection name contains the IP address from the iMap project engineering
(network view) and the PROFInet device name configured in iMap.
Parameter Meaning
Syntax [192.11.2.34|S7-300 Station (1)]
InitiateTimeout = 15000
Purpose If a connection establishment job cannot be
processed within the InitiateTimeout time, the
connection is reset and the job is started again.
Particularly when establishing connections using
DCOM from Microsoft, wait times of several
minutes can occur if the partner does not exist or if
the connection has broken down. During this time,
further actions on the connection are blocked
because the access is synchronous. This wait time
can be reduced with this parameter.
Default 10000
Possible Values milliseconds

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals