EasyManua.ls Logo

Siemens SIMOTICS L-1FN3 - Page 177

Siemens SIMOTICS L-1FN3
600 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data and characteristics
6.2 Data sheets and characteristics
1FN3 linear motors
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
175
1FN3050-1ND00-0xAx
Technical data
Designation
Unit
Value
Primary section main cooler data
Maximum dissipated thermal output
Q
P,H,MAX
kW
0.142
Recommended minimum volume flow rate
V
P,H,MIN
l/min
2.1
Coolant temperature rise
ΔT
P,H
K
0.97
Pressure drop
Δp
P,H
bar
0.359
Primary section precision cooler data
Maximum dissipated thermal output
Q
P,P,MAX
kW
0.00419
Recommended minimum volume flow rate
V
P,P,MIN
l/min
2.1
Pressure drop
Δp
P,P
bar
0.0555
Secondary section cooling data
Maximum dissipated thermal output
Q
S,MAX
kW
0.014
Recommended minimum volume flow rate
V
S,MIN
l/min
2.1
Pressure drop per meter of heatsink profile
Δp
S
bar
0.0286
Pressure drop per combi distributor
Δp
KV
bar
0.119
Pressure drop per coupling point
Δp
KS
bar
0.0877