Technical data and characteristics
6.2 Data sheets and characteristics
1FN3 linear motors
186 Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
6.2.2
1FN3100-xxxxx-xxxx
Data sheet of 1FN3100-1WC00-0xAx
1FN3100-1WC00-0xAx
Technical data
Designation
Unit
Value
General conditions
DC-link voltage
U
DC
V
600
Water cooling flow temperature
T
VORL
°C
35
Rated temperature
T
N
°C
120
Data at the rated point
Rated force
F
N
N
200
Rated current
I
N
A
2.44
Maximum velocity at rated force
v
MAX,FN
m/min
335
Rated power loss
P
V,N
kW
0.269
Limit data
Maximum force
F
MAX
N
490
Maximum current
I
MAX
A
6.5
Maximum velocity at maximum force
v
MAX,FMAX
m/min
147
Maximum electric power drawn
P
EL,MAX
kW
3.11
Static force
F
0
*
N
141
Stall current
I
0
*
A
1.72
Physical constants
Force constant at 20 °C
k
F,20
N/A
82
Voltage constant
k
E
Vs/m
27.3
Motor constant at 20 °C
k
M,20
N/(W)
0.5
14.4
Motor winding resistance at 20 °C
R
STR,20
Ω 10.8
Phase inductance
L
STR
mH 54.5
Attraction force
F
A
N 996
Thermal time constant
t
TH
s
120
Pole width
τ
M
mm 15
Mass of the primary section
m
P
kg
2
Mass of the primary section with precision cooler
m
P,P
kg
---
Mass of a secondary section
m
S
kg 0.7
Mass of a secondary section with heatsink profiles
m
S,P
kg
0.8
Primary section main cooler data
Maximum dissipated thermal output
Q
P,H,MAX
kW
0.24
Recommended minimum volume flow rate
V
P,H,MIN
l/min
2.5
Coolant temperature rise
ΔT
P,H
K
1.38
Pressure drop
Δp
P,H
bar
0.571