Configuration
5.2 Configuring workflow
1FN3 linear motors
104 Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Comments on system reactions
Installation information of the drive and control components
Energy considerations of the configured drive systems
You can find additional information that you can download in the Internet at SIZER
(https://support.industry.siemens.com/cs/document/54992004/sizer-for-siemens-
drives?dti=0&pnid=13434&lc=en-WW).
5.1.2
STARTER drive/commissioning software
The STARTER commissioning tool offers
Commissioning
Optimization
Diagnostics
Table 5- 1 Article number for STARTER
Commissioning tool
Article no. of the DVD
STARTER
German, English, French, Italian, Spanish
6SL3072-0AA00-0AG0
5.2
Configuring workflow
Requirements
The selection of a suitable linear motor depends on:
the peak force, effective force of the duty cycle and static force required for the
application
the desired velocity and acceleration
the installation space available
the desired or possible drive arrangement (e.g. single-sided, parallel, or double-sided
arrangement)
the required cooling system