Coupled motors
10.2 Master and stoker
1FN3 linear motors
576 Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Table 10- 3 Minimum distances between master and stoker
Primary section type
Same length
Distance between
housings D
Minimum distance M
Peak load motor
1FN3050-xW
3.5 mm
72.5 mm
1FN3100-xW
1FN3150-xW
1FN3300-xW
10.2 mm 111.2 mm
1FN3450-xW
1FN3600-xW
1FN3900-xW
Continuous load motor
1FN3050-xN
25.5 mm 102.5 mm
1FN3100-xN
1FN3150-xN
1FN3300-xN
46.2 mm 157.2 mm
1FN3450-xN
1FN3600-xN
1FN3900-xN
10.2.3
Parallel arrangement
The phase sequence U, V, W of the master and stoker is identical because the cable outlet
direction is the same. When the positioning of the master and stoker is correct, the pole
layout is identical on the two primary sections.
In the parallel arrangement, you can offset the primary sections by the distance A or the
secondary section tracks by the length B, if required.
Note
Offset factor
The offset factor i is an integer factor only.