Assembly drawings/dimension sheets
9.1 Position tolerance for mounting holes
1FN3 linear motors
510 Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
9.1
Position tolerance for mounting holes
Mounting holes
The following figure shows the position tolerances according to DIN EN ISO 1101 of the
mounting holes of the primary section and secondary section track. This information must be
available at the user's installation location.
Figure 9-1 Position tolerances for mounting holes
For secondary section tracks larger than 4 m, you must make the hole pattern for the
secondary sections according to the position tolerance.