EasyManuals Logo

Siemens SIMOTICS L-1FN3 Configuration Manual

Siemens SIMOTICS L-1FN3
600 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #476 background imageLoading...
Page #476 background image
Preparation for use
7.1 Transporting
1FN3 linear motors
474 Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Note
Original packaging
Keep the packaging of components with permanent magnets where possible!
When reusing the original packaging do not cover safety instructions that are possibly
attached. When required, use transparent adhesive tape for the packaging.
7.1
Transporting
Note
UN number for permanent magnets
UN number 2807 is allocated to permit magnets as hazardous item.
When shipping products that contain permanent magnets by sea or road, no additional
packaging measures are required for protection against magnetic fields.
7.1.1
Ambient conditions for transportation
Based on DIN EN 60721-3-2 (for transportation)
Table 7- 1 Climatic ambient conditions
Lower air temperature limit:
- 5 °C (deviates from 3K3)
Upper air temperature limit:
+ 40 °C
Lower relative humidity limit:
5%
Upper relative humidity limit:
85%
Rate of temperature fluctuations:
Max. 0.5 K/min
Condensation:
Not permissible
Formation of ice:
Not permissible
Transportation:
Class 2K2
Transport is only permissible in locations that are fully protected against the weather (in halls or rooms).

Table of Contents

Other manuals for Siemens SIMOTICS L-1FN3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS L-1FN3 and is the answer not in the manual?

Siemens SIMOTICS L-1FN3 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS L-1FN3
CategoryEngine
LanguageEnglish

Related product manuals