Technical data and characteristics
6.2 Data sheets and characteristics
1FN3 linear motors
204 Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Data sheet of 1FN3100-3WC00-0xAx
1FN3100-3WC00-0xAx
Technical data
Designation
Unit
Value
General conditions
DC-link voltage
U
DC
V
600
Water cooling flow temperature
T
VORL
°C
35
Rated temperature
T
N
°C
120
Data at the rated point
Rated force
F
N
N
675
Rated current
I
N
A
7.18
Maximum velocity at rated force
v
MAX,FN
m/min
303
Rated power loss
P
V,N
kW
0.748
Limit data
Maximum force
F
MAX
N
1650
Maximum current
I
MAX
A
19.1
Maximum velocity at maximum force
v
MAX,FMAX
m/min
137
Maximum electric power drawn
P
EL,MAX
kW
9.09
Static force
F
0
*
N
477
Stall current
I
0
*
A
5.08
Physical constants
Force constant at 20 °C
k
F,20
N/A
94
Voltage constant
k
E
Vs/m
31.3
Motor constant at 20 °C
k
M,20
N/W
0.5
29.1
Motor winding resistance at 20 °C
R
STR,20
Ω 3.47
Phase inductance
L
STR
mH 19.9
Attraction force
F
A
N 2990
Thermal time constant
t
TH
s 120
Pole width
τ
M
mm
15
Mass of the primary section
m
P
kg
5.6
Mass of the primary section with precision cooler
m
P,P
kg 6.4
Mass of a secondary section
m
S
kg
0.7
Mass of a secondary section with heatsink profiles
m
S,P
kg
0.8
Primary section main cooler data
Maximum dissipated thermal output
Q
P,H,MAX
kW
0.666
Recommended minimum volume flow rate
V
P,H,MIN
l/min
2.5
Coolant temperature rise
ΔT
P,H
K
3.83
Pressure drop
Δp
P,H
bar
1.49
Primary section precision cooler data
Maximum dissipated thermal output
Q
P,P,MAX
kW
0.0196
Recommended minimum volume flow rate
V
P,P,MIN
l/min
2.5
Pressure drop
Δp
P,P
bar
0.139