EasyManua.ls Logo

Siemens SIMOTICS L-1FN3 - Page 239

Siemens SIMOTICS L-1FN3
600 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data and characteristics
6.2 Data sheets and characteristics
1FN3 linear motors
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
237
Data sheet of 1FN3150-2WC00-0xAx
1FN3150-2WC00-0xAx
Technical data
Designation
Unit
Value
General conditions
DC-link voltage
U
DC
V
600
Water cooling flow temperature
T
VORL
°C
35
Rated temperature
T
N
°C
120
Data at the rated point
Rated force
F
N
N
675
Rated current
I
N
A
7.16
Maximum velocity at rated force
v
MAX,FN
m/min
306
Rated power loss
P
V,N
kW
0.671
Limit data
Maximum force
F
MAX
N
1650
Maximum current
I
MAX
A
19.1
Maximum velocity at maximum force
v
MAX,FMAX
m/min
141
Maximum electric power drawn
P
EL,MAX
kW
8.65
Static force
F
0
*
N
477
Stall current
I
0
*
A
5.06
Physical constants
Force constant at 20 °C
k
F,20
N/A
94.3
Voltage constant
k
E
Vs/m
31.4
Motor constant at 20 °C
k
M,20
N/W
0.5
30.8
Motor winding resistance at 20 °C
R
STR,20
Ω 3.13
Phase inductance
L
STR
mH 20
Attraction force
F
A
N 2990
Thermal time constant
t
TH
s 120
Pole width
τ
M
mm
15
Mass of the primary section
m
P
kg
5.3
Mass of the primary section with precision cooler
m
P,P
kg 6
Mass of a secondary section
m
S
kg
1.2
Mass of a secondary section with heatsink profiles
m
S,P
kg
1.3
Primary section main cooler data
Maximum dissipated thermal output
Q
P,H,MAX
kW
0.597
Recommended minimum volume flow rate
V
P,H,MIN
l/min
2.8
Coolant temperature rise
ΔT
P,H
K
3.07
Pressure drop
Δp
P,H
bar
1.49
Primary section precision cooler data
Maximum dissipated thermal output
Q
P,P,MAX
kW
0.0176
Recommended minimum volume flow rate
V
P,P,MIN
l/min
2.8
Pressure drop
Δp
P,P
bar
0.138

Table of Contents

Other manuals for Siemens SIMOTICS L-1FN3

Related product manuals