Technical data and characteristics
6.2 Data sheets and characteristics
1FN3 linear motors
306 Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Data sheet of 1FN3450-2WA50-0xAx
1FN3450-2WA50-0xAx
Technical data
Designation
Unit
Value
General conditions
DC-link voltage
U
DC
V
600
Water cooling flow temperature
T
VORL
°C
35
Rated temperature
T
N
°C
120
Data at the rated point
Rated force
F
N
N
1930
Rated current
I
N
A
8.91
Maximum velocity at rated force
v
MAX,FN
m/min
120
Rated power loss
P
V,N
kW
1.47
Limit data
Maximum force
F
MAX
N
5180
Maximum current
I
MAX
A
25
Maximum velocity at maximum force
v
MAX,FMAX
m/min
41
Maximum electric power drawn
P
EL,MAX
kW
15.1
Static force
F
0
*
N
1360
Stall current
I
0
*
A
6.3
Physical constants
Force constant at 20 °C
k
F,20
N/A
216
Voltage constant
k
E
Vs/m
72.2
Motor constant at 20 °C
k
M,20
N/W
0.5
59.5
Motor winding resistance at 20 °C
R
STR,20
Ω 4.42
Phase inductance
L
STR
mH 58.7
Attraction force
F
A
N 8820
Thermal time constant
t
TH
s 120
Pole width
τ
M
mm
23
Mass of the primary section
m
P
kg
16.5
Mass of the primary section with precision cooler
m
P,P
kg 17.7
Mass of a secondary section
m
S
kg
3.8
Mass of a secondary section with heatsink profiles
m
S,P
kg
4
Primary section main cooler data
Maximum dissipated thermal output
Q
P,H,MAX
kW
1.31
Recommended minimum volume flow rate
V
P,H,MIN
l/min
4
Coolant temperature rise
ΔT
P,H
K
4.69
Pressure drop
Δp
P,H
bar
0.371
Primary section precision cooler data
Maximum dissipated thermal output
Q
P,P,MAX
kW
0.0384
Recommended minimum volume flow rate
V
P,P,MIN
l/min
4
Pressure drop
Δp
P,P
bar
0.345

Table of Contents