EasyManua.ls Logo

Siemens SIMOTICS L-1FN3 - Page 359

Siemens SIMOTICS L-1FN3
600 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data and characteristics
6.2 Data sheets and characteristics
1FN3 linear motors
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
357
Data sheet of 1FN3450-3NA50-0xAx
1FN3450-3NA50-0xAx
Technical data
Designation
Unit
Value
General conditions
DC-link voltage
U
DC
V
600
Water cooling flow temperature
T
VORL
°C
35
Rated temperature
T
N
°C
120
Data at the rated point
Rated force
F
N
N
3890
Rated current
I
N
A
12.7
Maximum velocity at rated force
v
MAX,FN
m/min
69.9
Rated power loss
P
V,N
kW
2.08
Limit data
Maximum force
F
MAX
N
6600
Maximum current
I
MAX
A
26.7
Maximum velocity at maximum force
v
MAX,FMAX
m/min
34.3
Maximum electric power drawn
P
EL,MAX
kW
13
Static force
F
0
*
N
2800
Stall current
I
0
*
A
8.99
Physical constants
Force constant at 20 °C
k
F,20
N/A
312
Voltage constant
k
E
Vs/m
104
Motor constant at 20 °C
k
M,20
N/W
0.5
102
Motor winding resistance at 20 °C
R
STR,20
Ω 3.08
Phase inductance
L
STR
mH 81
Attraction force
F
A
N 13000
Thermal time constant
t
TH
s 180
Pole width
τ
M
mm
23
Mass of the primary section
m
P
kg
32.7
Mass of the primary section with precision cooler
m
P,P
kg 34.3
Mass of a secondary section
m
S
kg
3.8
Mass of a secondary section with heatsink profiles
m
S,P
kg
4
Primary section main cooler data
Maximum dissipated thermal output
Q
P,H,MAX
kW
1.84
Recommended minimum volume flow rate
V
P,H,MIN
l/min
4.5
Coolant temperature rise
ΔT
P,H
K
5.9
Pressure drop
Δp
P,H
bar
0.648
Primary section precision cooler data
Maximum dissipated thermal output
Q
P,P,MAX
kW
0.0546
Recommended minimum volume flow rate
V
P,P,MIN
l/min
4.5
Pressure drop
Δp
P,P
bar
0.546

Table of Contents

Other manuals for Siemens SIMOTICS L-1FN3

Related product manuals