EasyManua.ls Logo

Siemens SIMOTICS L-1FN3 - Page 362

Siemens SIMOTICS L-1FN3
600 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data and characteristics
6.2 Data sheets and characteristics
1FN3 linear motors
360 Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Data sheet of 1FN3450-3NB50-0xAx
1FN3450-3NB50-0xAx
Technical data
Designation
Unit
Value
General conditions
DC-link voltage
U
DC
V
600
Water cooling flow temperature
T
VORL
°C
35
Rated temperature
T
N
°C
120
Data at the rated point
Rated force
F
N
N
3890
Rated current
I
N
A
27.3
Maximum velocity at rated force
v
MAX,FN
m/min
165
Rated power loss
P
V,N
kW
2.07
Limit data
Maximum force
F
MAX
N
6600
Maximum current
I
MAX
A
57.4
Maximum velocity at maximum force
v
MAX,FMAX
m/min
90.5
Maximum electric power drawn
P
EL,MAX
kW
19.1
Static force
F
0
*
N
2800
Stall current
I
0
*
A
19.3
Physical constants
Force constant at 20 °C
k
F,20
N/A
145
Voltage constant
k
E
Vs/m
48.4
Motor constant at 20 °C
k
M,20
N/W
0.5
103
Motor winding resistance at 20 °C
R
STR,20
Ω 0.664
Phase inductance
L
STR
mH 17.5
Attraction force
F
A
N 13000
Thermal time constant
t
TH
s 180
Pole width
τ
M
mm
23
Mass of the primary section
m
P
kg
32.7
Mass of the primary section with precision cooler
m
P,P
kg 34.3
Mass of a secondary section
m
S
kg
3.8
Mass of a secondary section with heatsink profiles
m
S,P
kg
4
Primary section main cooler data
Maximum dissipated thermal output
Q
P,H,MAX
kW
1.83
Recommended minimum volume flow rate
V
P,H,MIN
l/min
4.5
Coolant temperature rise
ΔT
P,H
K
5.86
Pressure drop
Δp
P,H
bar
0.648
Primary section precision cooler data
Maximum dissipated thermal output
Q
P,P,MAX
kW
0.0542
Recommended minimum volume flow rate
V
P,P,MIN
l/min
4.5
Pressure drop
Δp
P,P
bar
0.546

Table of Contents

Other manuals for Siemens SIMOTICS L-1FN3

Related product manuals