EasyManua.ls Logo

Siemens SIMOTICS L-1FN3 - Page 483

Siemens SIMOTICS L-1FN3
600 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Preparation for use
7.2 Storage
1FN3 linear motors
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
481
Protection against humidity
If a dry storage area is not available, then take the following precautions:
Wrap the motor in humidity-absorbent material. Then wrap it in foil so that it is air tight.
Include several bags of desiccant in the sealed packaging. Check the desiccant and
replace it as required.
Place a humidity meter in the sealed packaging to indicate the level of air humidity
inside it.
Inspect the motor on a regular basis.
Protecting the cooling system for motors with integrated cooling
Before you store the motor after use, perform the following actions:
Empty the cooling channels.
Blow out the cooling ducts with dry, compressed air so that the cooling ducts are
completely empty.
Seal the connections of the cooling system.

Table of Contents

Other manuals for Siemens SIMOTICS L-1FN3

Related product manuals