Detailed description   
2.11 Supplementary conditions and NC VAR selector 
  Power Line Basic PLC Program (P3) 
2-90  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
Delete variables 
Variables are deleted in the window of selected variables by selecting the appropriate 
variables (single mouse click) and pressing the "Delete" key. No deletion action is taken with 
the doubleclick function. It is possible to select several variables for deletion (see "Selecting 
variables"). 
This action can also be undone under the "Edit" menu item. 
 
Note 
Deleting of variables results in a change of the absolute addresses of the pointer structures 
to the variables. When changing the variable selection, it is, therefore, absolutely necessary 
to generate one or several text files of all user blocksprior to the change. This is the only way 
to ensure that the assignment of the variables in FB "GET" or FB "PUT" remains correct, 
even after recompilation. 
Storing a selected list 
Once variables have been selected, they can be stored under a project name. The files are 
stored on a projectspecific basis. 
A window is displayed for the file to be stored. The project path and name for the file must be 
selected in the window. 
 
Fig. 2-28  Window for project path and name of file to be stored 
Code generation 
This menu item contains three selection options: 
1.  Settings (input of data block number to be generated) and other settings 
2.  Generate (create data block) 
3.  In the STEP 7 project (transferring the data block to a STEP 7 project)