Data Lists 
  5.1 Machine data 
Various NC/PLC Interface Signals and Functions (A2) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
5-3 
Number  Identifier: $MM_  Description 
9239    USER_END_WRITE_RPA_3  End of the third RPA area 
9240    USER_CLASS_WRITE_TOA_NAME  Change tool designation and duplo 
9241    USER_CLASS_WRITE_TOA_Type  Change tool type 
  9460  PROGRAMM_SETTINGS  Resetproof data storage for settings in the 
PROGRAM operating area 
  9461  CONTOUR_END_TEXT  String to be added to end of contour on 
completion of input 
  9478  TO_OPTION_MASK  Variants of tool offsets 
  9500  NC_PROPERTIES  NC_properties: Bit 0: Digital drives, 
Bit 1: Software startup switch 
9510    USER_CLASS_DIRECTORY1_P  Protection level for network drive 1 for 
PROGRAM operating area 
9511    USER_CLASS_DIRECTORY2_P  Protection level for network drive 2 for 
PROGRAM operating area 
9512    USER_CLASS_DIRECTORY3_P  Protection level for network drive 3 for 
PROGRAM operating area 
9513    USER_CLASS_DIRECTORY4_P  Protection level for network drive 4 for 
PROGRAM operating area 
9516    USER_CLASS_DIRECTORY1_M  Protection level for network drive 1 for 
MACHINE operating area 
9517    USER_CLASS_DIRECTORY2_M  Protection level for network drive 2 for 
MACHINE operating area 
9518    USER_CLASS_DIRECTORY3_M  Protection level for network drive 3 for 
MACHINE operating area 
9519    USER_CLASS_DIRECTORY4_M  Protection level for network drive 4 for 
MACHINE operating area 
 
5.1.2  NC-specific machine data 
 
Number  Identifier: $MN_  Description 
10350  FASTIO_DIG_NUM_INPUTS  Number of active digital NCK input bytes 
10360  FASTIO_DIG_NUM_OUTPUTS  Number of active digital NCK output bytes 
10361  FASTIO_DIG_SHORT_CIRCUIT  Short-circuit digital inputs and outputs 
11120  LUD_EXTENDED_SCOPE  Activate programglobal variables (PUD) 
11270  DEFAULT_VALUES_MEM_MSK  Activ.  
Function: Save DEFAULT values of GUD. 
18150  MM_GUD_VALUES_MEM  Reserve memory space for GUD