Axis Monitoring, Protection Zones (A3) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
3-1 
Supplementary Conditions 
3
3.1  3.1 Axis monitoring functions 
Settings 
For correct operation of the monitoring, the following settings must be made or checked, in 
addition to the machine data mentioned:  
General 
•  MD31030 $MA_LEADSCREW_PITCH (Leadscrew pitch)  
•  MD31050 $MA_DRIVE_AX_RATIO_DENOM (Denominator load gearbox)  
•  MD31060 $MA_DRIVE_AX_RATIO_NUMERA (Numerator load gearbox)  
•  MD31070 $MA_DRIVE_ENC_RATIO_DENOM (Denominator measuring gearbox)  
•  MD31080 $MA_DRIVE_ENC_RATIO_NUMERA (Numerator measuring gearbox)  
•  MD32810 $MA_EQUIV_SPEEDCTRL_TIME 
(Equivalent time constant speed control loop for feedforward control)  
•  Encoder resolution 
The corresponding machine data are described in: 
References: 
/FB/ Description of Functions Basic Machine; Velocities, Set/Actual Value Systems, 
Control (G2) 
Only drives with analog speed setpoint interface 
•  MD32260 $MA_RATED_VELO (Nominal motor speed)  
•  MD32250 $MA_RATED_OUTVAL (Nominal output voltage)