Detailed Description   
2.1 Mode group 
  Mode Group, Channel, Program Operation, Reset Response (K1) 
2-4  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
Example configuration: 
MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP[0] = 1 
MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP[1] = 2 
... 
MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP[3] = 0 ; gap 
... 
MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP[8] = 1 
MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP[9] = 2 
2.1.1  Mode group Stop 
Function 
The following NC/PLC interface signals are used to stop the traversing motions of the axes 
or of the axes and spindles in all mode group channels and to interrupt part program 
execution: 
•  DB11, ... DBX0.5 (mode group Stop) 
•  DB11, ... DBX0.6 (mode group Stop axes plus spindles) 
2.1.2  Mode group RESET 
Function 
A mode group Reset is requested via a mode group-specific NC/PLC interface signal: 
DB11, ... DBX0.7 = 1 (mode group reset)  
Sequence in the mode group channels 
•  Part program preparation (preprocessing) is stopped. 
•  All axes and spindles are decelerated to zero speed according to their acceleration 
curves without contour violation. 
•  Any auxiliary functions not yet output to the PLC are no longer output. 
•  The preprocessing pointers are set to the interruption point, and the block pointers are set 
to the beginning of the appropriate part programs. 
•  All initial settings, e.g., G function initial setting, are set to the parameterized values. 
•  All alarms with "Channel reset" criterion are canceled.