EasyManua.ls Logo

Siemens SINUMERIK 840DE SL - 2.2.2 Travel to fixed stop with hydraulic drives SIMODRIVE 6 digital (HLA module); 2.3 Travel to fixed stop with analog drives; 2.3.1 SIMODRIVE 611 analog (FDD)

Siemens SINUMERIK 840DE SL
2050 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Detailed Description
2.3 Travel to fixed stop with analog drives
Travel to Fixed Stop (F1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-27
2.2.2 Travel to fixed stop with hydraulic drives SIMODRIVE 611 digital (HLA module)
Velocity/force control
If the function FXS (FXS[x]=1) is activated for the hydraulic module 611 digital
(HLA module), only a change from velocity control to force control takes place. Positioning
from the NC is no longer possible in this case.
NC
When traveling to fixed stop, the NC evaluates a torque/force limit acting in addition to the
limits set on the drive:
Current
Force/torque
Power, pull-out power
Setup mode
Note
For a description of velocity and force control and special information about the
adjustments on SIMODRIVE 611 digital and digital (HLA module), please refer to:
References:
/FBHLA/ Description of Functions HLA Module; Drive Functions Firmware
/FB2/ Expansion functions; Compensation (K3); Chapter: Electronic weight compensation
2.3 2.3 Travel to fixed stop with analog drives
2.3.1 SIMODRIVE 611 analog (FDD)
Current/torque control
With the 611 analog (FDD), the torque control and torque limitation 611 analog (VSA) has
been realized as a current control/current limitation.