Data Lists 
   5.2 Signals 
Reference Point Approach (R1) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
5-3 
5.2  5.2 Signals 
5.2.1  Signals to BAG 
 
DB number  Byte.Bit  Name 
11, ...  0.7  Mode group RESET 
11, ...  1.2  Machine function: REF 
11, ...  5.2  Active machine function: REF 
 
5.2.2  Signals from BAG 
 
DB number  Byte.Bit  Name 
11, ...  5.2  Active machine function REF 
 
5.2.3  Signals to channel 
 
DB number  Byte.Bit  Name 
21, ...  1.0  Activate referencing 
21, ...  28.7  OEM channel signal (MMC → PLC) REF 
 
5.2.4  Signals from channel 
 
DB number  Byte.Bit  Name 
21, ...  33.0  Referencing active 
21, ...  35.7  Reset 
21, ...  36.2  All axes referenced