Detailed Description   
2.8 Other diagnostics tools 
  Diagnostic Tools (D1) 
2-30  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
Status display 
The status of the following data can be displayed on the operator panel. 
•  Interface signals from the machine control panel 
•  Interface signals to the machine control panel 
•  Interface signals between the NCK and PLC 
•  Interface signals between the MMC and PLC 
•  Data blocks (DB 0-127) 
•  Flags (FB 0-255) 
•  Timers (T 0-127) 
•  Counters (C 0-63) 
•  Inputs (IB 0-127) 
•  Outputs (QB 0-127) 
For a breakdown of the interface signals (DBx, DBBy), refer to: 
References: /IAD/, "Installation and Start-Up Guide" 
/IAF/, "Installation and Start-Up Guide" 
Change in status 
The status of the above signals can be changed for test purposes. Signal combinations are 
also possible. A maximum of ten operands can be altered at any one time. 
2.8  2.8 Other diagnostics tools 
611D startup tool 
Using the 611D startup tool and archiving software, the control can be evaluated and the 
control status can be saved. 
611D startup tool 
One of the functions of this program is to provide a tool 
•  For evaluating the most important values for the position, speed and current control 
•  For archiving drive and control data, and 
•  For analyzing the stated physical properties. 
For handling and complete range of functions see:  
References: /IAD/, "Installation and Start-Up Guide"