Detailed Description 
  2.4 Referencing with incremental measurement systems 
Reference Point Approach (R1) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-19 
2.4.5  Buffered actual value 
Automatic referencing 
Buffering the actual value enables "Automatic referencing" to be performed. With automatic 
referencing, machine axes with incremental measuring systems do not have to repeat the 
reference point approach in order to reference the measuring system following situations 
when the status of these axes is "Non-referenced". For example, this is the case after: 
•  POWER OFF/ON 
•  "Parking" selected 
DB31, ... DBB1.5/1.6 (position measuring system 1/2) = 0 
DB31, ... DBB2.1 (servo enable) = 0 
If the function is active, referencing is performed without axis motion by synchronizing the 
actual value system of the machine axis to the last valid actual value. The actual value is 
buffered in a retentive memory area of the control even after POWER OFF. 
 
 
Warning 
The machine axis must not be moved mechanically while the measuring system (encoder) of 
the machine axis is switched off (POWER OFF, axis "parked" etc.). This must be supported 
by the machine manufacturer with such measures as holding brakes, etc., and ensured by 
the user. Otherwise the actual value system of the machine axis will no longer be 
synchronized resulting in danger to personnel and machine. 
 
Precondition for automatic referencing 
At the time that automatic referencing occurs, e.g., after a POWER ON, when "parking" of 
machine axis is deactivated again, etc., the encoder status of the active measuring system of 
the machine axis must have the value 2: 
MD34210 $MA_ENC_REFP_STATE = 2 
That is, the encoder is referenced, an exact stop is reached, and automatic referencing is 
active the next time the encoder is activated. 
The following conditions must be fulfilled: 
•  "Automatic referencing" is assigned for the measuring system (encoder): 
MD34210 $MA_ENC_REFP_STATE = 1 
 
Encoder status = 1:  Automatic referencing enabled, but encoder not yet referenced or exact stop 
not reached.