Detailed Description 
  2.8 Auxiliary function output to PLC (H2) 
NC/PLC Interface Signals (Z1) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-79 
DB21, ... 
DBX318.5 
 
Associated M01/M00 active 
Edge evaluation: no  Signal(s) updated:  
Signal state 1 or  
edge change  
0 → 1 
This bit indicates that an M00 or M01 help function is active if the appropriate associated M00 and 
M01 (help functions) were enabled/activated beforehand. 
Signal state 0 or  
edge change  
1 → 0 
No associated M00/M01 help functions active. 
Corresponding to ....  DB 21; ... DBX30.5 (activate associated M01) 
 
2.8.3  Signals from axis/spindle (DB31, ...) 
DB31, ... 
DBD78 
 
Value of F help function 
Edge evaluation: no  Signal(s) updated: Job-controlled 
  The values of the F help functions for positioning axes are stored here. The axis to which each 
value applies is determined by the extended address. 
 
 
DB31, ... 
DBD86 
 
Value of M help function 
Edge evaluation: no  Signal(s) updated: Job-controlled 
  The values for the M3, M4, M5 help functions are sent to the associated interface for the addressed 
spindle. 
 
 
DB31, ... 
DBD88 
 
Value of S help function 
Edge evaluation: no  Signal(s) updated: Job-controlled  
  The values for the S help functions are sent to the associated interface for the addressed spindle.