Data Lists   
5.2 Signals 
  Reference Point Approach (R1) 
5-4  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
5.2.5  Signals to axis 
 
DB number  Byte.Bit  Name 
31, ...  1.4  Follow-up mode (request) 
31, ...  1.5/1.6  Position measuring system 1/position measuring system 2 
31, ...  2.4 - 2.7  Reference point value 1 to 4 
31, ...  4.6/4.7  Traversing keys minus/plus 
31, ...  12.7  Decelertion of reference point approach 
 
5.2.6  Signals from axis 
 
DB number  Byte.Bit  Name 
31, ...  60.4/60.5  Referenced, synchronized 1/Referenced, synchronized 2  
31, ...  61.3  Follow-up mode active 
31, ...  64.6/64.7  Traverse command minus/plus