Detailed Description   
2.9 Mode group, channel, program operation, reset response (K1) 
  NC/PLC Interface Signals (Z1) 
2-90  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
DB11, ... 
DBX7.2 
 
Active machine function REF 
Edge evaluation: no  Signal(s) updated: cyclic 
Signal state 1 or  
edge change  
0 → 1 
Machine function REF is active in the mode group. 
Signal state 0 or  
edge change  
1 → 0 
Machine function REF is not active. 
Further references  /FB1/ Description of Functions, Basic Machine; Reference Point Approach (R1) 
 
2.9.3  Signals to channel (DB21, ...) 
DB21, ... 
DBX0.4 
 
Activate single block 
Edge evaluation: no  Signal(s) updated: cyclic 
Signal state 1 or 
edge change 
0 → 1 
In AUTOMATIC and MDA modes, the operator must enable processing of each individual part 
program block of the part program selected in the channel by reactivating NC START. 
Signal state 0 or 
edge change 
1 → 0 
No effect. 
Special cases, 
errors, ...... 
•  In the case of active tool offset, intermediate blocks are inserted, when necessary. These blocks 
must also be enabled using NC START. 
•  In a series of G33 blocks, a single block is only operative if "dry run feed" is selected. 
•  In the case of a decoding single block, calculation blocks are not processed in the single step. 
Corresponds to ....  DB21, ... DBX35.3 (program status interrupted)