Detailed Description 
  2.4 Protection zones 
Axis Monitoring, Protection Zones (A3) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-31 
Maximum number of protection areas 
The maximum definable number of machine- and channel-related protection zones is set via: 
MD18190 $MM_NUM_PROTECT_AREA_NCK  
(Number of files for machine-related protection zones)  
MD28200 $MM_NUM_PROTECT_AREA_CHAN  
(Number of files for channel-specific protection zones)  
Absolute and relative protection zones 
The coordinates of a protection zone must always be programmed as absolute values with 
respect to the reference point of the protection zone. When the protection zone is activated 
via the part program it is possible to apply a relative offset to the reference point of the 
protection zone. 
Examples 
Below are a few examples of protection zones 
•  Toolrelated protection zone 
•  Workpiece-related protection zone 
•  3-dimensional protection zone 
•  Relative protection zone 
3
:
;
;
=
0
:RUNSLHFHUHODWHG
SURWHFWLRQ]RQHIRU
VSLQGOHFKXFN
7RROKROGHU
'ULOO
7RROUHODWHG
SURWHFWLRQ]RQH
IRUWRROKROGHU
 
Fig. 2-10  Example of application on turning machine