Detailed description 
  2.12 Block descriptions 
Power Line Basic PLC Program (P3) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-149 
  WVar10 :  WORD ; 
  WVar11 :  WORD ; 
  WVar12 :  WORD ; 
  WVar13 :  WORD ; 
  WVar14 :  WORD ; 
  WVar15 :  WORD ; 
  WVar16 :  WORD ; 
END_VAR 
VAR_OUTPUT 
  Error :  BOOL ; 
  Done :  BOOL ; 
  State :  WORD ; 
END_VAR 
 
Description of formal parameters 
The following table shows all formal parameters of the function PI_SERV. 
 
Signal  I/O  Type  Value range  Remarks 
Req  I  Bool    Job request 
PIService  I  Any  [DBName].[VarName] 
default is:"PI".[VarName] 
PI service description 
Unit  I  Int   1...  Area number 
Addr1 to 
Addr4 
I  Any  [DBName].[VarName]  Reference to strings specification according to 
selected PI service 
WVar1 to WVar16  I  Word   1...  Integers or word variables. Specification according 
to selected PI service 
Error  Q  Bool    Negative acknowledgment of job or execution of 
job impossible 
Done  Q  Bool    Job has been executed successfully 
State  Q  Word    See error identifiers 
 
Overview of additional PI services 
The following section provides an overview of the PI services that can be started from the 
PLC. The meaning and application of the general FB 7 input variables (Unit, Addr..., WVar...) 
depends on the individual PI service concerned. 
 
PI service  Function  Available in 
 D/810D 
TMFPBP  Empty location search  *(SW 4 and higher)