Detailed description 
  2.12 Block descriptions 
Power Line Basic PLC Program (P3) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-155 
FB9 call 
 
CALL  FB  9 , DB  109 ( 
  Ack  := Error_ack,    // e.g., MCP reset 
 OPMixedMode  := FALSE,   
  ActivEnable  = TRUE,  //  
  MCPEnable  := TRUE,   // Enable MCP switchover 
  Alarm1  := DB2.dbx188.0,  // Error message 700.100 
  Alarm2  := DB2.dbx188.1,  // Error message 700.101 
  Alarm3  := DB2.dbx188.2,  // Error message 700.102 
  Alarm4  := DB2.dbx188.3,  // Error message 700.103 
  Alarm5  := DB2.dbx188.4,  // Error message 700.104 
  Alarm6  := DB2.dbx188.5,  // Error message 700.105 
  Report  :=DB2.dbx192.0)  // Operational message 700.132 
 
 
 
Note 
Input parameter “MCPEnable” must also be set to true to enable MCP switchover. The 
default value of these parameters is set in this way and need not be specially assigned when 
the function is called. 
Alarm, error 
The output parameters "Alarm1" to "Alarm6" and "Report" can be transferred to the DB2 
areas for MMC alarm and error messages. 
If execution of an MMC function has failed (for which an appropriate error message cannot 
be displayed), status parameter ErrorMMC is set to 'logic 1' (e.g., booting error when no 
connection is made). 
Example of FB1 call (call in OB100) 
 
CALL "RUN_UP", "gp_par" ( 
 MCPNum  := 1, 
  MCP1In  := P#I 0.0, 
  MCP1Out   := P#Q 0.0, 
  MCP1StatSend  := P#Q 8.0, 
  MCP1StatRec  := P#Q 12.0, 
  MCP1BusAdr  := 255,  // Address of first MCP 
  MCP1Cycl   := S5T#200MS, 
  MCP1Stop  := TRUE,  // MCP disabled 
  NCCyclTimeout   := S5T#200MS, 
  NCRunupTimeout   := S5T#50S);