Detailed description   
2.12 Block descriptions 
  Power Line Basic PLC Program (P3) 
2-178  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
Timing diagram 
5HDG\
6WDUW
(UURU !
 
 
(1)   Activation of function 
(2)   Positive acknowledgment: Tool management has been transferred 
(3)   Reset function activation after receipt of acknowledgment 
(4)   Signal change by means of FB 
(5)   This signal chart is not permissible. The job must generally be terminated since the new tool 
positions must be forwarded to the tool management in the NCK. 
(6)   Negative acknowledgment: Error has occurred, error code in the output parameter "Error". 
 
Call example 
 
CALL FC 7 (  //Tool management transfer of block for revolver 
Start :=  m 20.5,  //Start := "1 " => transfer trigger 
ChgdRevNo :=  DB61.DBB 1, 
Ready :=  m 20.6, 
Error :=  DB61.DBW 12);  
u m 20.6;  //Poll ready 
r m 20.5;  //Reset start 
spb m001;  //Jumps, if everything OK 
l db61.dbw 12;  //Error information 
ow w#16#0;  //Evaluate error 
JC error;  //Jumps to troubleshooting, if <> 0 
m001:  //Start of another program 
error:  
r m 20.5;  //Reset start, if an error has occurred